Electronics-Related.com
Forums

What is the reason that the duty cycle for Boost Converter should be around 50%?

Started by Myauk December 8, 2011
Dear All,

Thank you so much for your kind suggestions on the design.

Now I have decided to boost 48V to 180V Maximum only. I have selected
150kHz operating frequency for Boost Converter, with inductor 25uA,
3A. And the rated power is supposed to be 250W. My question are:

1. Is the operating frequency and inductor value selected practical?
2. What are the important things to consider for sizing components in
this design?

regards
On Dec 13, 6:34=A0am, Myauk <aungkokot...@gmail.com> wrote:
> Dear All, > > Thank you so much for your kind suggestions on the design. > > Now I have decided to boost 48V to 180V Maximum only. I have selected > 150kHz operating frequency for Boost Converter, with inductor 25uA, > 3A. And the rated power is supposed to be 250W. My question are: > > 1. Is the operating frequency and inductor value selected practical? > 2. What are the important things to consider for sizing components in > this design? > > regards
1, Depends on core losses, switch losses and diode trr 2, Heat Most PFC's boost 0 to 141Vdc to 375Vdc with PW>80% for part of the input AC cycle. The trick is; BW<12Hz to control the dreaded RHPZ. Regards, Harry